Todd Products NMX-504-1212V 500 Watts AC Input Power Supply; Input Voltage Type: Continuous Range: 115V to 230V 8A/4A 50/60 Hz Simple Type: Power Supply

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 0.99 typical power factor
  • DC power good and ac power fail signals
  • Dual converter design eliminates interaction between logic and auxiliary outputs
  • Forced current sharing for N +1 redundancy
  • Low Ripple and noise on all outputs
  • Monotonic turn-on and turn-off
  • Remote sense on outputs #1 and 2
  • True remote inhibit
  • Universal AC input

Specifications

    General
  • AC Input: 90-264 Vac continuous range, 47 to 63 Hz; internally fused for 10 A
  • AC Power Fail: Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of ac power
  • Adjustability: Outputs #1 and 2 user adjustable ±5% minimum; Output #3 tracks #2; initial accuracy ±4%. Output #4 user adjustable ±5% minimum, or +5% only if voltage is 5.2 V
  • Brownout Protection: Holds regulation to 85 Vac
  • Conducted RFI: Meets FCC Part 15, Class A; EN55022 Class B
  • Cooling: 30 cfm required to achieve full ratings
  • Efficiency: 75% typical
  • Holdup Time: 20 ms minimum after removal of power at full load
  • Inrush: Cold start ac current is less than 30 A at 115 Vac and 60 A at 230 Vac. Limited by thermistor
  • Line & Load Reg: Outputs #1, 2, and 4 hold ±1% over ac input range and 0 to 100% load change; Output #3 requires 20% minimum load on outputs #2 and 3 to hold ±4%
  • Output Isolation: Isolated from ground 50 Vdc
  • Overload Protection: All outputs are protected against overload and short circuit; automatic recovery upon removal of fault
  • Power Factor: 0.99 typical at full load. Meets EN61000-3-2 Class A
  • Reverse Voltage: Protected against reverse voltage up to supply current rating
  • Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater
  • Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV EN60950, Class 1 SELV., CE 72/23/ EEC/93/68EEC (low voltage directive)
  • Stability: 0.1% over 8 hours after 30 minutes warm-up
  • Temperature Range: 0° to 50°C at full ratings
  • Thermal Protection: Shuts down power supply if overheated; automatic recovery

 

Applications