Todd Products NMX-504-1212V 500 Watts AC Input Power Supply; Input Voltage Type: Continuous Range: 115V to 230V 8A/4A 50/60 Hz Simple Type: Power Supply
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- 0.99 typical power factor
- DC power good and ac power fail signals
- Dual converter design eliminates interaction between logic and auxiliary outputs
- Forced current sharing for N +1 redundancy
- Low Ripple and noise on all outputs
- Monotonic turn-on and turn-off
- Remote sense on outputs #1 and 2
- True remote inhibit
- Universal AC input
Specifications
- AC Input: 90-264 Vac continuous range, 47 to 63 Hz; internally fused for 10 A
- AC Power Fail: Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of ac power
- Adjustability: Outputs #1 and 2 user adjustable ±5% minimum; Output #3 tracks #2; initial accuracy ±4%. Output #4 user adjustable ±5% minimum, or +5% only if voltage is 5.2 V
- Brownout Protection: Holds regulation to 85 Vac
- Conducted RFI: Meets FCC Part 15, Class A; EN55022 Class B
- Cooling: 30 cfm required to achieve full ratings
- Efficiency: 75% typical
- Holdup Time: 20 ms minimum after removal of power at full load
- Inrush: Cold start ac current is less than 30 A at 115 Vac and 60 A at 230 Vac. Limited by thermistor
- Line & Load Reg: Outputs #1, 2, and 4 hold ±1% over ac input range and 0 to 100% load change; Output #3 requires 20% minimum load on outputs #2 and 3 to hold ±4%
- Output Isolation: Isolated from ground 50 Vdc
- Overload Protection: All outputs are protected against overload and short circuit; automatic recovery upon removal of fault
- Power Factor: 0.99 typical at full load. Meets EN61000-3-2 Class A
- Reverse Voltage: Protected against reverse voltage up to supply current rating
- Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater
- Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV EN60950, Class 1 SELV., CE 72/23/ EEC/93/68EEC (low voltage directive)
- Stability: 0.1% over 8 hours after 30 minutes warm-up
- Temperature Range: 0° to 50°C at full ratings
- Thermal Protection: Shuts down power supply if overheated; automatic recovery
Applications
- None Available
Aliases